Tomzn Tovpd1-60-ec Manual __link__ -

Improper wiring can permanently damage the device or create a severe electrical hazard. Always shut off the main breaker before handling the wires.

The installation of the Tomzn TOVPD1-60-EC should be performed by a qualified electrician to ensure safety and compliance with local electrical codes. It is typically installed at the point of entry of the electrical supply into a building or in a distribution panel. This strategic placement allows it to protect all downstream electrical devices. tomzn tovpd1-60-ec manual

Widen the delta between the Trip Value () and Recovery Value ( A3/A6 ). Persistent over-current trips The load demands more amperage than configured. Improper wiring can permanently damage the device or

: Limits current to prevent circuit damage (adjustable up to 63A). Automatic Recovery It is typically installed at the point of

Includes lightning protection and heat dissipation capabilities up to 105℃.

Displays Active Power (kW) or Cumulative Energy Consumption (kWh). Indicator LEDs: KV: Kilovolts / Voltage status.

Press and hold the button for 3 seconds. The screen will flash, displaying the first parameter code ( A1 ). Parameter Configuration Table Parameter Function Adjustable Range Factory Default A1 Power-on delay time (Boot time) 1s – 500s A2 Over-voltage protection value 230V – 300V (or OFF) A3 Over-voltage recovery value 225V – 295V A4 Over-voltage protection action time 0.1s – 30s A5 Under-voltage protection value 140V – 210V (or OFF) A6 Under-voltage recovery value 145V – 215V A7 Under-voltage protection action time 0.1s – 30s A8 Over-current protection value 1A – 63A (or OFF) A9 Over-current protection action time 0.1s – 30s A10 Fault recovery delay time 1s – 500s A11 Continuously over-current fault times 1 – 20 times (or OFF) Saving Settings

Ready to get vertical?
CHECK OUT THE RESOURCES SECTION TO LEARN MORE ABOUT VERTICAL CABINETS >
PLEASE NOTE: This site only provides artwork to enhance your gaming experience – it does not include the games themselves, or the MAME software required to run them. Learn more about MAME and download it here, or read this quick introduction to how it works. Copyrights are property of their original or current owners, and this site is not affiliated with any game developer, publisher or manufacturer. See the About page for more info.